The original product was anasbestos cement product known as super six manufactured by james hardie co.
Super 6 roofing sheets.
Marley roofing south africa from our trusted m22 m11 double roman roof tiles to our innovative solar tiles and eco tuff range we ve got you covered.
Bayling roofing specialise in metal roofing polycarbonate roofing fibreglass roofing as well as cladding gutters downpipes and insulation on the central coast of nsw.
The roof was in excellent condition for long but over the past few months there were a few incidents of tree branches falling on the roof during heavy winds causing small portions of the roof on the edges to break off.
If you live anywhere else in australia and have corrugated cement fencing it will be super 6 and contain asbestos.
Asbestos super six roof sheeting.
Roof is in okay condition but don t like the thought of an asbestos roof.
It was also made in a shallower profile known as standard which is very similar in profile to corrugated metal roofing and has 25mm 1 inch corrugations.
Super 6 was not the only rounded profile used.
Super six fastener design.
Super six should be screw fixed to either timber or steel purlins.
Asbestos fibres are frequently found in the ceiling space below a super six roof.
For sale approximately 3 x 3 7m colour corodek and approximately 5 plus sheets in colour trim clad and harmony ranging from 2m to 1 2m 80 8 steel stud framing panels 2 145m x 1 2m 180 james hardie fibre cement sheets new style super 6 no asbestos 11 sheets at 1550mm 4 sheets at 1450mm 2 sheets at approximately 1 2m the lot 150 for further information or inspection phone or email thanks.
The use of the appropriate length of 12g or 14g screw will ensure failure by screw pull out will not occur under loads within the scope of the limit state load roofing span capacity chart.
Can get it blown in but costs so much as they need to remove some of the sheets to get insulation in.
This can occur in a number of ways two examples are given below.
Fibres in the ceiling space.
Item 749971 model 1214a.
Plus want to insulate but as its a flat roof no access.
Super six repair sheet call us on 02 4324 5555.
Small cracks in the super six over time.
Since these breakages have caused the cross section of the sheet to be exposed.
So at least if we replace super six we can insulate while the roof is off.
The asbestos test data shows that large quantities of fibres are found in rainwater from a pva sealed super six roof.
Tuftex seacoaster 2 2 ft x 8 ft corrugated clear pvc plastic roof panel.